FMS has many successful projects, and our clients recognising our high quality work with multiple contracts over many years. Out recent projects include:

  • Canberra Playhouse Theatre, 2014
    Provide New Boiler, Pump and Associated Works.
  • Canberra Theatre, 2013, $700,000
    Complete Central Chiller Plant Room Upgrade, including: Provide new Chillers, cooling Towers, Pumps, All Pipework, New MSSB, Controls, Plantroom Complete Repaint and Associated Works.
  • Canberra Playhouse Theatre, 2012, $250,000
    Provide new chiller, pumps and associated pipework. Provide additional pipework, electrical, etc. for emergency chiller connection points.
  • Goodwin Homes Aged Care, Monash, 2015
    Air Conditioning Upgrade to Medical Clinic.
  • Vikings Club, Erindale, 2015
    Administration, TAB and Sports Bar Upgrade.
  • Canberra Hospital, Endoscopy Unit, 2014
    Ductwork modifications for New Fitout.
  • Baringa Childcare Centre, 2014
    Canteen Kitchen Upgrade.
  • Manuka Oval, 2012, $150,000
    Provide VRF Air Conditioning Systems to Serve the Players Areas.

Canberra Institute of Technology
multiple contracts from $10,000 to $220,000 between 2005 and 2011

  • Reid Campus, HVAC upgrade to Block H to reduce system transmitted noise.
  • Reid Campus, HVAC upgrade to Block E – design, modify, relocate and provide new s/a & r/a delivery systems to suit refurbished block layout. Provide air balance.
  • Reid Campus, Kitchen upgrade, Mechanical Services; including ventilation; heating & stainless steel commercial kitchen hoods throughout Teaching Kitchen.
  • Reid Campus, Extend dust extraction system in Cabinet-making Workshop
  • Bruce Campus, Provide Dust Extraction System to Carpentry (Stage 3)
  • Bruce Campus, Provide sanding booths to Cabinet-making Workshop (stage 2); New sanding booths installed with rooftop discharge ductwork
  • Bruce Campus, Provide new Dust Extraction Systems to Cabinet-making Workshop (stage 1) and Carpentry Workshop.

Department of Defence
multiple contracts from $100,000 to $250,000 between 2007 and 2012

  • Russell Offices, Install new computer room air conditioning units.
  • Russell Offices, Upgrade Air Conditioning to the Situation Room.
  • Russell Offices, Upgrade Air Conditioning to Defence Chief’s Reception.
  • Russell Offices, Install two A/C units into Computer Server Room.
  • Russell Offices, Install two Chilled Water A/C units into Computer Server Room; provide new pipework from central chiller plant.

Primary Schools
multiple contracts from $50,000 to $200,000 between 2006 and 2009

  • Hawker Primary School, Provide VRF Air - Conditioning to Administration Building; including HHW pipework upgrade.
  • Macgregor Primary School, Upgrade Main Mechanical Switchboard.
  • Macgregor Primary School, Provide new condensing Boilers, Pipework & Pumps.
  • Mawson Primary School, Provide 125x new HHW radiators, valves and Pipework Modifications.
  • Mawson Primary School, Upgrade HHW radiators.
  • Gold Creek Primary School, Provide Air conditioning to Library Block. Add on cooling installed into existing Ducted Heating system.
  • Latham Primary School, Replace HHW Pipework; Replace rusted out steel pipework with rooftop pipework.
  • Kaleen Primary School, Provide Ducted Evaporative Cooling to Classrooms.
  • Melrose Primary School, Upgrade existing Boiler, Flue, etc.

Education facilities, government departments and more:

  • Black Mountain Childcare Centre
    Provide full Mechanical Services to facility, including VRF A/C units, exhaust systems, etc.
  • Erindale Pool, Pool Heating Plant
    Provide supplementary Boiler; Upgrade Heat Exchangers & system Pumps; and associated electrical & Pipework.
  • Hawker College
    Provide platforms for Rooftop Packaged Air Conditioning units to three locations, inclusive of service platforms.
  • Stirling Centre for Teaching and Learning
    Upgrade to existing Air Handling Units to provide cooling coils , pipework and damper installation.
  • Emergency Services Agency, Fairbairn
    Provide complete HVAC services, including Boilers for in-slab heating, A/C units, air & water delivery systems.
  • Lyons Education Facility
    Provide Air-conditioning to Offices and Conference Rooms.
  • Calwell High School
    Upgrade Technology area Fume Extraction Systems.
  • Isabella Plains School
    Mechanical Upgrade to School; inclusive of Packaged Ducted AC units, Multi-head hi-wall units; gas furnaces; and associated piping, electrical and controls works.
  • Amaroo School
    Upgrade Heating To Admin Block; inclusive of providing new Fan Coil Units, complete pipework and boiler upgrade.
  • Dickson College
    Upgrade Spray Painting Booth.
  • 10 Moore Street, Canberra City
    Cooling Tower Pipework & Pump Upgrade.
  • ACT Health Building, 1 Moore Street, Canberra City
    Upgrade Cooling Tower Pipework.
  • CDSC Offices Fyshwick
    Ductwork and controls modifications to Classrooms to improve the system performance.